Post by longhorn on Jul 6, 2006, 3:50am
I have a 64 swap meet special, the only thing 64, is the left case. I've made my own wiring harness, who knows if it's right, although I was riding her tonight. I have a Cycle Electric generator, I have the B terminal to the positive side of the battery, I have the wire off of the A terminal running to a "Short Stop", (I also have the neutral switch, and the oil pressure switch running to the same SS), The other wire from the "SS" to the ignition switch. When I turned the ignition switch on, the generator light came on, when I started the bike, the light stayed on. As I revved the engine the light got brighter, and I think burned out. What am I doing wrong? Jim
Post by fourthgear on Jul 6, 2006, 12:25pm
longhorn
What is the short stop you are referring to? Circuit breaker? The Gen. light
should come on when you turn the ign. switch on, but getting brighter
is not supposed to happen upon revving , it should go out if you are
charging. I had a grounded wire to the Gen. once and it fried the bulb
in the Gen. light , something to check. You should also check your charging
system for proper operation. You also don't say anything about a voltage
reg. or relay. If you wired it your self , what wiring schematic did
you go by?
Post by longhorn on Jul 9, 2006, 12:53am
Fourthgear; The short stop is a circuit breaker, I use-em in my shovels, for insurance. I'm not really using a schematic, just punting. I like to think I know what I'm doing, obviously I don't! I did get the generator light to go out, for about 15 miles. Then it came back on, I think my charging system is junk,460 miles per generator-regulator, not good. Anybody have a decent Harley 65 generator? The generator showed 16 volt's going to the battery, not sure if the regulator or the generator, is junk? Had to recharge my battery after limping home. Any idea's on how to test each component? Thank's Jim
Post by fourthgear on Jul 10, 2006, 12:54pm
lonhorn
Look into the knowledge base on this sight and look at electrical, on the
third page for wiring schematics to double check how it compares with
yours , you may have missed something . 16 volts is kinda high , was
that at 2000 rpms? It appears your system is (charging ) putting out
,but high and how old is your Battery ? Do you have a Panhead service
manual ? If not you should get at least one if you don't already, they
have all the testing procedures in them.
Post by kell on Jul 10, 2006, 4:40pm
Your post is kind of confusing.
What kind of regulator do you have, is it mechanical or solid state? Is the
regulator a separate unit, or is it the end cap CE regulator, or what?
From your post I would have almost guessed you didn't have a regulator
at all, but you said something about a B terminal, so you must have one.
I've never worked with mechanical regulators, but you would wire a solid state
regulator like this: a wire should go from the generator's A terminal directly
into the appropriate connection on the regulator. another wire should go
from the generator's F terminal directly to the appropriate connection on
the regulator. The battery should get wired to yet another connection on
the regulator (presumably the one you called "B"). And the regulator
needs a good ground.
Somebody will correct me if I'm wrong, but I think that mechanical regulators
use the same wiring scheme.